LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Histological Comparative Analysis of Bowman's Layer Grafts Procured Using 3 Different Techniques.

Photo from wikipedia

Supplemental Digital Content is Available in the Text. Purpose: The objective of this study is to perform a histological analysis of Bowman layer (BL) grafts. Methods: BL grafts were procured… Click to show full abstract

Supplemental Digital Content is Available in the Text. Purpose: The objective of this study is to perform a histological analysis of Bowman layer (BL) grafts. Methods: BL grafts were procured from 13 human cadaver corneal tissues using 3 different donor preparation techniques. Subsequently, the grafts were fixed in 10% buffered formalin phosphate and embedded in paraffin. Hematoxylin and eosin sections of BL grafts were obtained and analyzed under a light microscope. BL and full graft thickness were measured using an image-processing software. Results: All 13 BL grafts contained residual anterior stromal tissue. BL stripping using Kelman-McPherson and Moorfield forceps (technique 3) achieved the thinnest graft thickness with a mean full graft thickness of 18.7 μm (95% confidence interval [CI], −9.8 to 47.2) at the thinnest point of the graft, whereas BL procurement using the Melles lamellar dissector (technique 2) led to the highest mean full graft thickness of 279.9 μm (95% CI, 251.4–308.5) even at the thinnest area of the graft. By contrast, BL dissection using a blunt dissector (technique 1) provided a mean full graft thickness of 70.2 μm (95% CI, 40.4–100.1) at the graft's thinnest point. Although peripheral graft tears occurred in 50%, 50%, and 100% of techniques 1, 2, and 3, respectively, intact 6.25-mm diameter BL grafts could be secured in 50%, 100%, and 80% of techniques 1, 2, and 3, respectively. Conclusions: None of the techniques used led to the procurement of pure BL grafts devoid of the anterior stroma. Peripheral scoring with a thin needle and tissue manipulation with Kelman-McPherson and Moorfield forceps led to the thinnest grafts in this study.

Keywords: layer grafts; analysis bowman; graft; graft thickness; bowman layer

Journal Title: Cornea
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.