LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Contamination of multiuse eyedrop bottles by exhaled air from patients wearing face masks during the COVID-19 pandemic: Schlieren imaging analysis.

Photo by gryffyn1 from unsplash

PURPOSE To determine whether mask-induced redirected exhaled air through the superior mask gap contacts multiuse eyedrop bottles during drop administration and the efficacy of interventions to reduce such exposure. SETTING… Click to show full abstract

PURPOSE To determine whether mask-induced redirected exhaled air through the superior mask gap contacts multiuse eyedrop bottles during drop administration and the efficacy of interventions to reduce such exposure. SETTING Academic ophthalmology center. DESIGN Interventional analysis. METHODS Schlieren airflow imaging was taken of an examinee wearing frequently used face masks and enacting common clinical scenarios-with and without manual occlusion of the superior mask gap and/or neck extension-and maximum visible vertical breath plume height was quantified. Bottle height during eyedrop administration was measured for 4 ophthalmologists during instillation to 8 eyes of 4 subjects. RESULTS Breath plume height (mean ± SD 275.5 ± 16.3 mm) was significantly greater than mean bottle height (13.9 ± 4.7 mm; P < .01). Plume height was reduced with manual mask occlusion vs without (P < .01) and was also lower than mean bottle height with manual mask occlusion (P < .01) but not in the absence of occlusion (P < .01). Neck extension alone did not adequately redirect liberated breath to prevent contact with a bottle. CONCLUSIONS Exhaled air liberated from commonly worn patient face masks was able to contact multiuse eyedrop bottles during eyedrop administration. These findings have important patient safety implications during the coronavirus disease 2019 pandemic and with other respiratory pathogens because these multiuse bottles could potentially serve as vectors of disease. Occlusion of the superior mask gap significantly reduces breath contamination and should be strongly considered by eyecare providers during drop administration in eye clinics.

Keywords: eyedrop bottles; mask; multiuse eyedrop; exhaled air; face masks

Journal Title: Journal of cataract and refractive surgery
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.