Left ventricular assist devices (LVADs) require anticoagulation therapy with vitamin K antagonists to reduce the risk of thrombotic events. The quality of anticoagulation may be assessed by the time in… Click to show full abstract
Left ventricular assist devices (LVADs) require anticoagulation therapy with vitamin K antagonists to reduce the risk of thrombotic events. The quality of anticoagulation may be assessed by the time in therapeutic range (TTR). We analyzed a retrospective cohort of LVAD patients at a single institution from January 2012 to September 2014. Primary outcomes included TTR during the study time period and TTR 30 days preceding a bleeding or thrombotic event. Fifty-one patients (mean age 57.0 ± 14.6 years; 78% male) had an overall TTR of 52%. Median international normalized ratio (INR) preceding a bleeding and thrombotic event was 2.7 and 2.2, respectively (p = 0.049). In the 30 days before an event, patients with a bleeding event were more likely to be on low-dose aspirin (37% vs. 12%; p = 0.018) and spend a higher proportion of time above therapeutic range (41% vs. 17%; p = 0.007) compared with those with thrombotic events. The association between a greater percentage of time above therapeutic range in the 30 days before a bleeding event demonstrates the importance of avoiding a supratherapeutic INR in the LVAD patient population and the usefulness of TTR as a measure of the overall quality of anticoagulation and monitoring in an LVAD cohort.
               