We sought to assess the impact of temporary preoperative mechanical circulatory support (TPMCS) on heart transplantation outcomes. A total of 4,060 adult heart transplants from June 1, 2006, to December… Click to show full abstract
We sought to assess the impact of temporary preoperative mechanical circulatory support (TPMCS) on heart transplantation outcomes. A total of 4,060 adult heart transplants from June 1, 2006, to December 31, 2019, were identified in the Scientific Registry of Transplant Recipients database as having TPMCS. Recipients were divided into groups based on their type of TPMCS: intra-aortic balloon pump (IABP), temporary ventricular assist device (VAD), biventricular assist device (BIVAD), and extracorporeal membrane oxygenation (ECMO). Perioperative outcomes and survival were compared among groups. Recipients with IABP were associated with older age, a smoking history, and a significantly shorter wait list time (p < 0.01). Recipients with ECMO had a significantly increased in-hospital mortality as well as an increased incidence of dialysis (p < 0.01). Kaplan-Meier analysis revealed worse 1 and 5 year survival for recipients with ECMO. Cox model demonstrated a significantly increased risk of mortality with BIVAD (hazard ratio [HR], 1.33; 95% CI, 1.12–1.57; p < 0.01) and ECMO (HR, 1.64; 95% CI, 1.33–2.03; p < 0.01). While patients with IABP have a survival comparable to patients without TPMCS or durable left VAD, outcomes for BIVADs and ECMO are not as favorable. Transplantation centers must continue to make careful choices about the type of TPMCS utilized before heart transplant.
               