LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of single and double dorsal wires in the extension block technique for mallet fractures

Photo from wikipedia

Abstract Mallet fractures are avulsion fractures of the extensor tendon from the distal phalanx base and often occur due to sudden flexion or axial loading. In this study, we aimed… Click to show full abstract

Abstract Mallet fractures are avulsion fractures of the extensor tendon from the distal phalanx base and often occur due to sudden flexion or axial loading. In this study, we aimed to compare the clinical and radiological results of patients treated with single and double dorsal wires from the dorsal in the extension block method. Patients to whom a single wire from dorsal was applied were assigned to Group 1 (n: 22), and those to whom double wires were applied were assigned to Group 2 (n: 23). Surgical treatment was decided for patients with more than 1/3 of the fracture fragment containing the joint surface and volar subluxation. The range of motion of the distal interphalangeal (DIP) joint was measured with a goniometer. The displacement of the fragment was measured before and after surgery on lateral radiographs. The presence of bridging callus formation on anterior-posterior and lateral radiographs was evaluated for a union. There were 30 male (66.7%) and 15 (33.3%) female patients. The mean age of the patients was 32 years. Radiographic union was obtained in all patients. Pseudoarthrosis was not observed in any patient. The Crawford score was excellent in 13 (28.9%) cases, the score was good in 18 (40%) cases, the scores were moderate in 13 (28.9%) cases, and the score was poor in 1 case (2.2%). There were no complications in 35 (77.8%) cases, dorsal bump complications occurred in 9 cases (20%), and osteoarthritis and dorsal bump complications occurred in 1 (2.2%) case. We did not observe nail deformity, skin necrosis, infection, or fingertip sensitivity. We found similar functional and clinical results between the groups. We recommend using single dorsal wire, as using double dorsal wires requires extra operation time, effort, and fluoroscopy.

Keywords: double dorsal; dorsal wires; extension block; single double; mallet fractures; dorsal

Journal Title: Medicine
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.