LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Improved Identification of Venous Thromboembolism From Electronic Medical Records Using a Novel Information Extraction Software Platform

Photo from wikipedia

Introduction: The United States federally mandated reporting of venous thromboembolism (VTE), defined by Agency for Healthcare Research & Quality Patient Safety Indicator 12 (AHRQ PSI-12), is based on administrative data,… Click to show full abstract

Introduction: The United States federally mandated reporting of venous thromboembolism (VTE), defined by Agency for Healthcare Research & Quality Patient Safety Indicator 12 (AHRQ PSI-12), is based on administrative data, the accuracy of which has not been consistently demonstrated. We used IDEAL-X, a novel information extraction software system, to identify VTE from electronic medical records and evaluated its accuracy. Methods: Medical records for 13,248 patients admitted to an orthopedic specialty hospital from 2009 to 2014 were reviewed. Patient encounters were defined as a hospital admission where both surgery (of the spine, hip, or knee) and a radiology diagnostic study that could detect VTE was performed. Radiology reports were both manually reviewed by a physician and analyzed by IDEAL-X. Results: Among 2083 radiology reports, IDEAL-X correctly identified 176/181 VTE events, achieving a sensitivity of 97.2% [95% confidence interval (CI), 93.7%–99.1%] and specificity of 99.3% (95% CI, 98.9%–99.7%) when compared with manual review. Among 422 surgical encounters with diagnostic radiographic studies for VTE, IDEAL-X correctly identified 41 of 42 VTE events, achieving a sensitivity of 97.6% (95% CI, 87.4%–99.6%) and specificity of 99.8% (95% CI, 98.7%–100.0%). The performance surpassed that of AHRQ PSI-12, which had a sensitivity of 92.9% (95% CI, 80.5%–98.4%) and specificity of 92.9% (95% CI, 89.8%–95.3%), though only the difference in specificity was statistically significant (P<0.01). Conclusion: IDEAL-X, a novel information extraction software system, identified VTE from radiology reports with high accuracy, with specificity surpassing AHRQ PSI-12. IDEAL-X could potentially improve detection and surveillance of many medical conditions from free text of electronic medical records.

Keywords: information extraction; radiology; novel information; extraction software; medical records; electronic medical

Journal Title: Medical Care
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.