Assessing the Validity of Measurements of Swept-source and Partial Coherence Interferometry Devices in Cataract Patients.

Photo from wikipedia

SIGNIFICANCE The validity of measurements of OA-2000 (Tomey, Nagoya, Japan), a new swept-source optical coherence tomography-based biometer, was evaluated in comparison with IOLMaster 500 (Carl Zeiss Meditec AG, Jena, Germany)… Click to show full abstract

SIGNIFICANCE The validity of measurements of OA-2000 (Tomey, Nagoya, Japan), a new swept-source optical coherence tomography-based biometer, was evaluated in comparison with IOLMaster 500 (Carl Zeiss Meditec AG, Jena, Germany) as a reference method for optical biometry in cataract patients. PURPOSE This article compares the validity of measurements between OA-2000 and IOLMaster 500. METHODS In this cross-sectional study, axial length, lens thickness, anterior chamber depth, and keratometry readings were obtained by the OA-2000 and IOLMaster 500. Two measurements were taken by each method. Patients in which any one of the biometry methods could not be performed owing to severity of the cataract were excluded from the study. Repeatability of measurements was presented by coefficient of variation, and Bland-Altman method was used for evaluating the agreement between the two biometers. RESULTS Fifty-eight eyes of 58 cataract patients with mean ± standard deviation age of 61.4 ± 8.3 years were included in this study. Intraclass correlation ranged from 0.898 to 0.901 and showed good to excellent reliability. It was good for keratometry 1 (0.898) and excellent for keratometry 2 (0.992), axial length (0.999), and anterior chamber depth (0.901). Bland-Altman analysis showed good agreement between the swept-source optical coherence tomography and partial coherence interferometry devices for axial length, anterior chamber depth, and mean keratometry, with narrow 95% limits of agreement (-0.09 to 0.1 mm, -0.33 to 0.54 mm, -0.97 to 1.03 D, respectively), and also indicated small mean difference (0.01 for axial length, 0.11 for anterior chamber depth, 0.03 for mean keratometry, respectively) for all comparisons. CONCLUSIONS OA-2000 as a new swept-source optical coherence tomography has an excellent repeatability for measurement of biometric data in cataract patients, comparing with the standard partial coherence interferometry biometer (IOLMaster 500).

Keywords: validity measurements; swept source; cataract patients; coherence; partial coherence

Journal Title: Optometry and Vision Science
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.