LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Case Report: Multimodal, Longitudinal Assessment of Retinal Structure and Function following Laser Retinal Injury

Photo from wikipedia

SIGNIFICANCE This case report demonstrates the use of novel imaging techniques and functional tests to longitudinally evaluate retinal structure and function after laser retinal injury. The structural and functional prognosis… Click to show full abstract

SIGNIFICANCE This case report demonstrates the use of novel imaging techniques and functional tests to longitudinally evaluate retinal structure and function after laser retinal injury. The structural and functional prognosis could be predicted with clinical findings, high-resolution retinal imaging, and functional testing. PURPOSE We present a laser retinal injury case in which an adaptive optics scanning laser ophthalmoscope and adaptive optics–based psychophysics were used to examine and monitor retinal structure and function after accidental exposure to a 1-W infrared laser beam. CASE REPORT A 23-year-old patient was unwittingly exposed to a 1-W, 852-nm continuous-wave laser at work as they noticed a small central blurry spot in the right eye. An initial eye examination was done 1 day after exposure, and the right eye's acuity was 20/25−2. Posterior segment evaluation revealed disrupted outer retina near the right eye's fovea. Adaptive optics imaging 2 weeks after the exposure revealed a 0.50 × 0.75° elliptical area with irregular borders and abnormal cone reflectivity just below the fovea. Starting at 1-month follow-up, structural recovery was observed on optical coherence tomography (OCT). Subsequent adaptive optics imaging showed significant recovery of cone reflectivity. Importantly, adaptive optics microperimetry showed measurable detection thresholds at all affected retinal locations at 6 months. By 10 months, all sites exhibited normal sensitivities. CONCLUSIONS Retinal structure and function from laser injury can be visualized and measured with OCT, adaptive optics imaging, and psychophysics. An intact Bruch's membrane on OCT and measurable retinal sensitivity by adaptive optics microperimetry may serve as good biomarkers for retinal recovery.

Keywords: structure function; adaptive optics; optics; retinal structure; case

Journal Title: Optometry and Vision Science
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.