LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Single-Energy Retrospective Metal Artifact Reduction Using Adaptive Thresholding for Metal Implants in the Abdomen and Pelvis

Photo from wikipedia

Objective To assess impact of single-energy metal artifact reduction (SEMAR) algorithm utilizing retrospective adaptive thresholding in reducing metal artifacts in the abdomen and pelvis. Methods In this prospective institutional review… Click to show full abstract

Objective To assess impact of single-energy metal artifact reduction (SEMAR) algorithm utilizing retrospective adaptive thresholding in reducing metal artifacts in the abdomen and pelvis. Methods In this prospective institutional review board–approved, Health Insurance Portability and Accountability Act–compliant study, 90 patients with various metals (n = 97) on computed tomography of abdomen and pelvis (Canon Medical, Aquilion ONE and PRIME) scanned 07/2017–09/2018 with SEMAR retrospectively applied were included. Density was measured in the near and far field to the metals. Density standard deviation (SD), representing artifact severity, was compared with and without SEMAR applied. Two trained human observers independently evaluated severity of artifacts on a five-point scale (0, no artifact; 5, severe artifact). Results The SEMAR significantly decreased artifact severity in the near field of high-density metal implants (SD of 204 ± 101HU without vs. 66 ± 40HU with SEMAR, P < 0.001). In the far field, the artifact severity was similar (40 ± 31HU without vs. 36 ± 27HU with SEMAR, P = 0.41). Artifact severity was decreased adjacent to low-density metal in the near field (SD of 86 ± 56HU without vs 49 ± 30HU with SEMAR, P < 0.001). In the far field to the low-density metals artifact severity was similar (33 ± 29HU without vs. 31 ± 27HU with SEMAR, P = 0.79). Subjectively, artifacts severity decreased for high-density metals in near field by 1.3 ± 1.0, and in far field by 0.7 ± 0.7 and for low-density metals in the near field by 0.7 ± 1.0, far field 0.4 ± 0.5, all P < 0.05. Conclusions The SEMAR retrospective algorithm with adaptive thresholding subjectively and objectively reduced near-field artifacts generated by high- and low-density metals.

Keywords: field; semar; metal; density; adaptive thresholding; severity

Journal Title: Journal of Computer Assisted Tomography
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.