Purpose The purpose of this paper is the proposal of fatigue-life-prediction curve for cast aluminum alloy A356-T6 with different casting defect sizes. Design/methodology/approach Four kinds of A356-T6 fatigue specimens were… Click to show full abstract
Purpose The purpose of this paper is the proposal of fatigue-life-prediction curve for cast aluminum alloy A356-T6 with different casting defect sizes. Design/methodology/approach Four kinds of A356-T6 fatigue specimens were sampled from the actual large-scale cast component, where the cooling rates were different. In addition, three kinds of A356 were casted under different casting conditions to simulate different defect sizes in the actual component. Subsequently, rotating bending fatigue tests were conducted using those samples. The maximum sizes of casting defects were quantitatively evaluated through microstructural observation and extreme value statistics. The fatigue limits of all samples were predicted using hardness and defect sizes based on modified Murakami’s equation. Findings The modified equation for fatigue limit prediction in A356-T6 was proposed. Fatigue limits were successfully predicted using the proposed equation. Originality/value Fatigue limit prediction method using hardness and maximum defect size was limited to steels. This paper proposed the modified method for A356-T6 aluminum alloy with lower elastic modulus. The method was valid for A356-T6 with different defect sizes.
               