Aiming at the problem that it is difficult to model and analyze the thermal effect of large motors as a whole, a method based on fluid network decoupling is proposed… Click to show full abstract
Aiming at the problem that it is difficult to model and analyze the thermal effect of large motors as a whole, a method based on fluid network decoupling is proposed to solve the global thermal effect of large motors. Taking YJKK500-4 2500-kW compact medium-sized high-voltage motor as an example, combined with the internal structure and the actual size of the motor, and using the flow-heat coordination mechanism and the fluid network, the whole internal ventilated paths of motor are divided into four equal pressure regions: end, stator-rotor, end, and internal fan according to the magnitude of pressure. The reasonable basic assumptions and boundary conditions are selected to link each region, which can avoid the problem that the inlet boundary condition is difficult to give. After that, the internally ventilated paths are modeled and analyzed, and the fluid flow and temperature in each region of the internally ventilated paths are obtained. Combined with the experimental data, the calculation results are all within the error. The rationality and correctness of the method used in the paper are confirmed, which solves the problem that the ordinary computer cannot calculate the huge model of large motor and provides a basis for the calculation of similar motor in the future.
               