Remote Measurement of Human Vital Signs Based on Joint-Range Adaptive EEMD

Photo by paipai90 from unsplash

Remote techniques for measuring human vital signs have attracted great interests due to the benefits shown in medical monitoring and military applications. Compared with continuous-wave Doppler radar, frequency-modulated continuous-wave (FMCW)… Click to show full abstract

Remote techniques for measuring human vital signs have attracted great interests due to the benefits shown in medical monitoring and military applications. Compared with continuous-wave Doppler radar, frequency-modulated continuous-wave (FMCW) radar which can discriminate vital signs from different distances, shows potential for reducing the interferences from other targets and the environment. However, in the state-of-the-art algorithms, only one chirp per frame is utilized for FMCW-based vital sign monitoring. Moreover, the vital signal is extracted from only one range bin of the fast Fourier transform. Which does not make full utilization of the long system idle time, and loses the power distributed on other range bins. By exploiting the relationship between respiration and heartbeat vibrations, an adaptive identification embedded ensemble empirical mode decomposition (EEMD) method for joint-range spectral estimation is proposed to measure the heart rate. First, A multi-chirp processing is presented for a 2-dimensional phase accumulation. Then the phase signals from a sequence of range bins are decomposed with a fast adaptive identification process. Finally, with the identified heartbeat components, we solve a multiple measurement vectors problem to estimate the heart rate. Experimental results showed that, at the detection range from 1 m~ 2.5 m, the proposed method can robustly distinguish the heartbeat from respiration and its harmonics and accurately estimate the heart rate with a root mean square error less than 6 bpm.

Keywords: human vital; heart rate; vital signs; range; joint range; measurement

Journal Title: IEEE Access
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.