LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A Core Body Temperature Retrieval Method for Microwave Radiometry When Tissue Permittivity is Unknown

Photo from wikipedia

This paper presents a novel method for core temperature retrieval using microwave radiometry when complex permittivity and heat transfer parameters of the tissue layers of the human subject are unknown.… Click to show full abstract

This paper presents a novel method for core temperature retrieval using microwave radiometry when complex permittivity and heat transfer parameters of the tissue layers of the human subject are unknown. Previous works present methods for core temperature retrieval, but these methods do not account for population variation in the relevant electromagnetic and thermal parameters, which can increase measurement error beyond the clinically acceptable limit of 0.5 °C. Pennes’ bioheat model of a six-tissue-layer human head model combined with a coherent electromagnetic model simulate experimental data. To retrieve core temperature, nonlinear least squares optimization is then used to minimize the difference between the simulated experimental data and an exponential model for physical temperature and the coherent electromagnetic model. By using 20 frequencies spanning from 1-5 GHz, core temperature is retrieved while accounting for population variation in the permittivity and thermal parameters. A Monte Carlo simulation in which the thermal parameters and permittivity vary according to literature derived, population-representative distributions and the core body temperature varies from 18 to 46 °C is used to assess the utility of the retrieval method. Different antenna patterns are tested to explore the effect on retrieval accuracy. The retrieval method has a retrieval error of <0.1 °C when only the thermal parameters are unknown and a retrieval error of <0.5 °C when the thermal parameters and permittivity are unknown, which is within the clinically acceptable error range of 0.5 °C. These results help progress the field of medical microwave radiometry toward being a clinically viable noninvasive measurement that is accurate when measuring all patients.

Keywords: core; permittivity; microwave radiometry; thermal parameters; temperature; temperature retrieval

Journal Title: IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.