LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Accurate and Standardized Coronary Wave Intensity Analysis

Photo from wikipedia

Objective: Coronary wave intensity analysis (cWIA) has increasingly been applied in the clinical research setting to distinguish between the proximal and distal mechanical influences on coronary blood flow. Recently, a… Click to show full abstract

Objective: Coronary wave intensity analysis (cWIA) has increasingly been applied in the clinical research setting to distinguish between the proximal and distal mechanical influences on coronary blood flow. Recently, a cWIA-derived clinical index demonstrated prognostic value in predicting functional recovery post-myocardial infarction. Nevertheless, the known operator dependence of the cWIA metrics currently hampers its routine application in clinical practice. Specifically, it was recently demonstrated that the cWIA metrics are highly dependent on the chosen Savitzky–Golay filter parameters used to smooth the acquired traces. Therefore, a novel method to make cWIA standardized and automatic was proposed and evaluated in vivo. Methods: The novel approach combines an adaptive Savitzky–Golay filter with high-order central finite differencing after ensemble-averaging the acquired waveforms. Its accuracy was assessed using in vivo human data. The proposed approach was then modified to automatically perform beatwise cWIA. Finally, the feasibility (accuracy and robustness) of the method was evaluated. Results: The automatic cWIA algorithm provided satisfactory accuracy under a wide range of noise scenarios ($\leq$ 10% and $\leq$ 20% error in the estimation of wave areas and peaks, respectively). These results were confirmed when beat-by-beat cWIA was performed. Conclusion: An accurate, standardized, and automated cWIA was developed. Moreover, the feasibility of beatwise cWIA was demonstrated for the first time. Significance: The proposed algorithm provides practitioners with a standardized technique that could broaden the application of cWIA in the clinical practice as well as enabling multicenter trials. Furthermore, the demonstrated potential of beatwise cWIA opens the possibility of investigating the coronary physiology in real time.

Keywords: coronary wave; wave intensity; intensity analysis; tex math; cwia; inline formula

Journal Title: IEEE Transactions on Biomedical Engineering
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.