LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Epidermal Electrode Technology for Detecting Ultrasonic Perturbation of Sensory Brain Activity

Photo from wikipedia

Objective: We aim to demonstrate the in vivo capability of a wearable sensor technology to detect localized perturbations of sensory-evoked brain activity. Methods: Cortical somatosensory evoked potentials (SSEPs) were recorded… Click to show full abstract

Objective: We aim to demonstrate the in vivo capability of a wearable sensor technology to detect localized perturbations of sensory-evoked brain activity. Methods: Cortical somatosensory evoked potentials (SSEPs) were recorded in mice via wearable, flexible epidermal electrode arrays. We then utilized the sensors to explore the effects of transcranial focused ultrasound, which noninvasively induced neural perturbation. SSEPs recorded with flexible epidermal sensors were quantified and benchmarked against those recorded with invasive epidural electrodes. Results: We found that cortical SSEPs recorded by flexible epidermal sensors were stimulus frequency dependent. Immediately following controlled, focal ultrasound perturbation, the sensors detected significant SSEP modulation, which consisted of dynamic amplitude decreases and altered stimulus-frequency dependence. These modifications were also dependent on the ultrasound perturbation dosage. The effects were consistent with those recorded with invasive electrodes, albeit with roughly one order of magnitude lower signal-to-noise ratio. Conclusion: We found that flexible epidermal sensors reported multiple SSEP parameters that were sensitive to focused ultrasound. This work therefore 1) establishes that epidermal electrodes are appropriate for monitoring the integrity of major CNS functionalities through SSEP; and 2) leveraged this technology to explore ultrasound-induced neuromodulation. The sensor technology is well suited for this application because the sensor electrical properties are uninfluenced by direct exposure to ultrasound irradiation. Significance: The sensors and experimental paradigm we present involve standard, safe clinical neurological assessment methods and are thus applicable to a wide range of future translational studies in humans with any manner of health condition.

Keywords: flexible epidermal; brain activity; technology; perturbation; epidermal electrode

Journal Title: IEEE Transactions on Biomedical Engineering
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.