Measuring Orthopedic Plate Strain to Track Bone Healing Using a Fluidic Sensor Read via Plain Radiography

Photo from wikipedia

Objective: We describe a fluidic X-ray visualized strain indicator under applied load (X-VISUAL) to quantify orthopedic plate strain and inform rehabilitative care. Methods: The sensor comprises a polymeric device with… Click to show full abstract

Objective: We describe a fluidic X-ray visualized strain indicator under applied load (X-VISUAL) to quantify orthopedic plate strain and inform rehabilitative care. Methods: The sensor comprises a polymeric device with a fluidic reservoir filled with a radio-dense fluid (cesium acetate) and an adjoining capillary wherein the liquid level is measured. A stainless-steel lever attaches to the plate and presses upon the acrylic bulb with a displacement proportional to plate bending strain. The sensor was attached to a plate in a Sawbones composite tibia mimic and a human cadaveric tibia. An osteotomy model (5 mm gap) was used to simulate an unstable fracture, and allograft repair to simulate a stiffer healed fracture. The cadaveric and Sawbones tibia were cyclically loaded five times (0–400 N) using a mechanical test stand, and fluid displacement was measured from plain radiographs. Results: The sensor displayed reversible and repeatable behavior with a slope of 0.096 mm/kg and fluid level noise of 50–80 micrometer (equivalent to 5–10 N). The allograft-repaired composite fracture was 13 times stiffer than the unstable fracture. Conclusion: An analysis of prior external fracture fixation studies and fatigue curves for internal plates indicates that the threshold for safe weight bearing should be 1/5th–1/10th of the initial bending for an unstable fracture. The precision of our device (<2% body weight) should thus be sufficient to track fracture healing from unstable through safe weight bearing. Significance: The X-VISUAL fluidic sensor enables orthopedic plate strain quantification to monitor facture healing via X-ray imaging.

Keywords: orthopedic plate; plate strain; fracture; sensor; plate

Journal Title: IEEE Transactions on Biomedical Engineering
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.