Open-switch faults in inverter-driven electric drives have recently gained increasing attention in the scientific community. Since these faults may lead to undesired effects, their fast and unambiguous detection is desirable.… Click to show full abstract
Open-switch faults in inverter-driven electric drives have recently gained increasing attention in the scientific community. Since these faults may lead to undesired effects, their fast and unambiguous detection is desirable. This paper proposes a detection algorithm for open-switch faults, which is based on the observation of the current control deviation and a subsequent test procedure. This algorithm detects the fault immediately after its occurrence within a few switching periods, even during transient operation. The proposed method is tested via simulations and experiments at different operating points of a surface permanent magnet drive.
               