Power-electronic-converter-induced motor bearing currents are a widespread problem in the field of electrical drives. Parasitic capacitances between the electrical machine's parts provide a path for leakage currents, which finally harm… Click to show full abstract
Power-electronic-converter-induced motor bearing currents are a widespread problem in the field of electrical drives. Parasitic capacitances between the electrical machine's parts provide a path for leakage currents, which finally harm metallic ball bearings. Remembering that end-windings have a significant contribution in building up stray capacitances, a countermeasure affecting both the lamination stack and end-winding areas is needed. This article focuses on a countermeasure against the noncirculating bearing currents in the cluster of solutions at the motor side. The electrostatic shielding approach, which is a known principle to reduce capacitive couplings, is applied in electrical machines every now and then. In this article, the principle of slot-embedded grounded electrodes is extended to cover also the end-windings. Thus, the electrodes provide a better shaft-to-ground voltage mitigating effect compared to the case where electrodes are applied only in the lamination stack area. The feasibility and effectiveness of such a countermeasure are investigated. Different options in terms of scaling of both the machine size and diameter of the electrodes were analyzed and corresponding conclusions were pointed out.
               
Click one of the above tabs to view related content.