LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study

Photo from wikipedia

Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and… Click to show full abstract

Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and following that to the hotspot temperature (HST). In this article, a novel formula is proposed for HST prediction of DTs by considering the effective electrical and mechanical parameters on heat dissipation capacity. Additionally, complete and accurate 3D modeling based on computational fluid dynamics (CFD) is presented to validate the proposed novel formula for HST prediction. In this modeling, the conservator, which plays a key role in the HST value, is accurately modeled. Optical fiber sensors are utilized in the studied 500-kVA DT to verify the accuracy of the proposed HST prediction formula during the experimental temperature rise test. Experimental results show that the proposed formula is highly accurate and has an acceptable correlation with the empirical values. The root-mean-square error, mean error, and average error percentage (AEP) of the proposed formula are 0.3 °C, 0.3 °C, and 0.37%, respectively, in HST transient values, and 0.3 °C, 0.3 °C, and 0.29% in HST steady-state values, which substantiate the precision and proficiency of the proposed HST prediction formula rather than IEC and IEEE equations. Finally, a thermal camera is employed to verify the results of CFD-based 3D modeling in top-oil temperature, bottom-oil temperature, and conservator oil temperature during the experimental tests. According to the measurement results, temperatures of CFD-based 3D simulation and thermal camera in the aforementioned three points are in good agreement with each other and AEP is less than 1.4%, which indicates the accuracy and efficiency of the proposed 3-D modeling.

Keywords: oil; distribution transformers; formula; temperature; prediction; hst

Journal Title: IEEE Transactions on Industrial Electronics
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.