LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Balanced Dual-Side LCC Compensation in IPT Systems Implementing Unity Power Factor for Wide Load Range and Misalignment Tolerance

Photo by mbrunacr from unsplash

Misalignment tolerance and wide load range capability are necessary for a practical inductive power transfer system. In pursuit of high performance, input unity power factor and high efficiency are expected.… Click to show full abstract

Misalignment tolerance and wide load range capability are necessary for a practical inductive power transfer system. In pursuit of high performance, input unity power factor and high efficiency are expected. In this article, a balanced design method of dual-side LCC compensation is proposed to achieve input unity power factor over wide misalignment and load ranges. With the proposed method, dual-side LCC compensation is in a balanced state where zero phase angle frequencies coincide with designed voltage gain frequencies under coupling and load variations. Unity power factor can be implemented while maintaining voltage gain with frequency control. Possible output power versus frequency characteristics of this balanced dual-side LCC compensation are categorized and fully analyzed. One of them, with strong power regulation capability and high misalignment adaptability, is selected as the design target. Coil currents are optimized using a surplus degree of design freedom while selecting parameters. Unity power factor and coil current optimization ensure low losses in devices and coils, which benefits system efficiency. Thus, a wide load range, high misalignment tolerance, nearly zero reactive power, and high efficiency can be simultaneously implemented. The proposed method is verified on a 2.1 kW prototype. The coil size of both primary and secondary sides is 600 mm × 600 mm, and the air gap is 150 mm. Load power varies from 10% to 100% within the coupling range from 0.15 to 0.35. Nearly unity power factor is realized under various working conditions. The maximum dc–dc efficiency reaches 96.4%.

Keywords: power; unity power; power factor; load; dual side

Journal Title: IEEE Transactions on Industrial Electronics
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.