This study proposes a hybrid method for improving the magnetic shielding performance of a magnetic shielding room (MSR) with few permalloy layers. In this method, two types of compensating coils… Click to show full abstract
This study proposes a hybrid method for improving the magnetic shielding performance of a magnetic shielding room (MSR) with few permalloy layers. In this method, two types of compensating coils are combined, one placed outside the MSR and the other placed inside. The coupling effect between the outside coil and the permalloy layer is used to adjust the residual field distribution characteristics of the MSR, and the inside coil is used to compensate for the adjusted residual field. This method has been verified with an MSR with two permalloy layers and an inner space of 1.3 × 1.3 × 2.2 m. According to the result, the residual field was reduced to less than 2.5 nT in a cube with a 0.4-m side length, which is seven times lower than that without compensation, and the inner space utilization rate was also improved by two times compared with existing MSRs with a comparable space size. The proposed method is of great significance in the development of magnetic shielding technology.
               