LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Peak Shift in Field-Swept Magnetic Particle Spectroscopy: A Novel Sensing Metric for Magnetic Nanoparticle Bioassays

Combining magnetic particle spectroscopy (MPS) with functionalized magnetic nanoparticles (MNPs) has the potential to provide a rapid, sensitive, and user-friendly point-of-care (PoC) testing platform. Conventional MPS techniques typically apply harmonic… Click to show full abstract

Combining magnetic particle spectroscopy (MPS) with functionalized magnetic nanoparticles (MNPs) has the potential to provide a rapid, sensitive, and user-friendly point-of-care (PoC) testing platform. Conventional MPS techniques typically apply harmonic ratios (such as, the third to fifth harmonic ratio) as the sensing metric to eliminate interference caused by MNP concentration. However, the quantification accuracy of this approach largely depends on the consistency of the signal-to-noise ratio (SNR) between the selected harmonics, imposing stringent requirements on hardware design and the nonlinear magnetic behavior of the MNPs. In this study, we introduce “peak shift” to field-swept MPS (FS-MPS) as a novel metric for MNP characterization and biosensing. An integrated FS-MPS device is used to capture the second harmonic spectrum, which records the second harmonic amplitudes under different perpendicular static magnetic fields. Importantly, the peak position of the spectrum remains constant under different MNP concentrations and shifts upon changes in MNP hydrodynamic size. In this way, the peak shift sensitively detects MNP binding to the targeted analytes, enabling robust biosensing based solely on the second harmonics. The feasibility of the proposed method was demonstrated using streptavidin-grafted MNPs and biotinylated polystyrene beads. Diagnostic performance was assessed using ACE2 functionalized MNPs and SARS-CoV-2 S1 protein and SARS-CoV-2 pseudovirus assays. The proposed strategy can detect virus concentrations as low as 350 TCID50/mL. Additionally, a good linear correlation exists between the peak shift and virus titer in the 350–7000 TCID50/mL range, demonstrating the potential of our method to quantify virus content.

Keywords: spectroscopy; particle spectroscopy; shift field; magnetic particle; peak shift; sensing metric

Journal Title: IEEE Transactions on Instrumentation and Measurement
Year Published: 2024

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.