In this article, an improved dc capacitor voltage balancing control is proposed for single-phase cascaded H-bridge (CHB) multilevel converters. Compared with conventional voltage balancing control methods, the proposed scheme has… Click to show full abstract
In this article, an improved dc capacitor voltage balancing control is proposed for single-phase cascaded H-bridge (CHB) multilevel converters. Compared with conventional voltage balancing control methods, the proposed scheme has a comprehensive consideration of three aspects while balancing the capacitor voltages among H-bridges: coupling effect elimination, reactive power balancing, and dynamic performance improvement. First, the system mathematical model in the d–q reference frame is derived, and the relationship among duty cycle modifications of H-bridges is revealed to eliminate the coupling effect of voltage balancing control on the current control loop. Then, based on the H-bridge power model, a quantitative solution for reactive power balancing is presented to design the reactive duty cycle modifications. In order to enhance the dynamic performance of voltage balancing control, a dynamic references design method is adopted to evaluate the active duty cycle modifications. Finally, both simulation and experimental results are presented to validate the effectiveness of the proposed scheme.
               