LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Hadamard-Encoded Synthetic Transmit Aperture Imaging for Improved Lateral Motion Estimation in Ultrasound Elastography

Photo by cassidykdickens from unsplash

Lateral motion estimation has been a challenge in ultrasound elastography mainly due to the low resolution, low sampling frequency, and lack of phase information in the lateral direction. Synthetic transmit… Click to show full abstract

Lateral motion estimation has been a challenge in ultrasound elastography mainly due to the low resolution, low sampling frequency, and lack of phase information in the lateral direction. Synthetic transmit aperture (STA) can achieve high resolution due to two-way focusing and can beamform high-density image lines for improved lateral motion estimation with the disadvantages of low signal-to-noise ratio (SNR) and limited penetration depth. In this study, Hadamard-encoded STA (Hadamard-STA) is proposed for the improvement of lateral motion estimation in elastography, and it is compared with STA and conventional focused wave (CFW) imaging. Simulations, phantom, and in vivo experiments were conducted to make the comparison. The normalized root mean square error (NRMSE) and the contrast-to-noise ratio (CNR) were calculated as the evaluation criteria in the simulations. The results show that, at a noise level of −10 dB and an applied strain of −1% (compression), Hadamard-STA decreases the NRMSEs of lateral displacements by 46.92% and 35.35%, decreases the NRMSEs of lateral strains by 52.34% and 39.75%, and increases the CNRs by 9.70 and 9.75 dB compared with STA and CFW, respectively. In the phantom experiments performed on a heterogeneous tissue-mimicking phantom, the sum of squared differences (SSD) between the reference and the motion-compensated RF data, and the CNR were calculated as the evaluation criteria. At an applied strain of −1.80%, Hadamard-STA is found to decrease the SSDs by 20.91% and 30.99% and increase the CNRs by 14.15 and 24.66 dB compared with STA and CFW, respectively. In the experiments performed on a breast phantom, Hadamard-STA achieves better visualization of the breast inclusion with a clearer boundary between the inclusion and the background than STA and CFW. The in vivo experiments were performed on a patient with a breast tumor, and the tumor could also be better visualized with a more homogeneous background in the strain image obtained by Hadamard-STA than by STA and CFW. These results demonstrate that Hadamard-STA achieves a substantial improvement in lateral motion estimation and maybe a competitive method for quasi-static elastography.

Keywords: motion estimation; lateral motion; sta; motion; hadamard

Journal Title: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.