LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Regularized Ultrasound Phantom-Free Local Attenuation Coefficient Slope (ACS) Imaging in Homogeneous and Heterogeneous Tissues

Photo from wikipedia

Attenuation maps or measurements based on the local attenuation coefficient slope (ACS) in quantitative ultrasound (QUS) have shown potential for the diagnosis of liver steatosis. In liver cancers, tissue abnormalities… Click to show full abstract

Attenuation maps or measurements based on the local attenuation coefficient slope (ACS) in quantitative ultrasound (QUS) have shown potential for the diagnosis of liver steatosis. In liver cancers, tissue abnormalities and tumors detected using ACS are also of interest to provide new image contrast to clinicians. Current phantom-based approaches have the limitation of assuming a comparable speed of sound between the reference phantom and insonified tissues. Moreover, these methods present the inconvenience for operators to acquire data on phantoms and patients. The main goal was to alleviate these drawbacks by proposing a methodology for constructing phantom-free regularized (PF-R) local ACS maps and investigate the performance in both homogeneous and heterogeneous media. The proposed method was tested on two tissue-mimicking media with different ACS constructed as homogeneous phantoms, side-by-side and top-to-bottom phantoms, and inclusion phantoms with different attenuations. Moreover, an in vivo proof-of-concept was performed on healthy, steatotic, and cancerous human liver datasets. Modifications brought to previous works include: 1) a linear interpolation of the power spectrum in the log scale; 2) the relaxation of the underlying hypothesis on the diffraction factor; 3) a generalization to nonhomogeneous local ACS; and 4) an adaptive restriction of frequencies to a more reliable range than the usable frequency range. Regularization was formulated as a generalized least absolute shrinkage and selection operator (LASSO), and a variant of the Bayesian information criterion (BIC) was applied to estimate the Lagrangian multiplier on the LASSO constraint. In addition, we evaluated the proposed algorithm when applying median filtering before and after regularization. Tests conducted showed that the PF-R yielded robust results in all tested conditions, suggesting potential for additional validation as a diagnosis method.

Keywords: attenuation; attenuation coefficient; phantom; coefficient slope; local attenuation; slope acs

Journal Title: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.