LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Pilot Study to Detect Changes in Blood Flow in the External Auditory Meatus During Hemodialysis

Photo from wikipedia

Blood flow to internal organs is reported to fall during hemodialysis (HD). As such, noninvasive monitoring devices are required to detect changes in perfusion, which could then be used for… Click to show full abstract

Blood flow to internal organs is reported to fall during hemodialysis (HD). As such, noninvasive monitoring devices are required to detect changes in perfusion, which could then be used for therapeutic interventions. We report on a pilot study monitoring blood flow in the outer auditory meatus. We measured the maximum pulse wave amplitude and indicators of blood flow by analyzing red and green color changes in the outer auditory meatus from video recordings made using an otoscope fitted with a digital camera during HD treatments. We studied 61 patients, 43 (71.5%) male, mean age 64.9 ± 12.7 years. Weight fell from 72.8 ± 22.5 kg predialysis to 71.5 ± 22.1 kg postdialysis (P < 0.001). BP did not significantly change (predialysis 142 ± 29/67 ± 18 to 143 ± 25/68 ± 17 mm Hg postdialysis). The maximum pulse wave amplitude in the external auditory meatus fell from 0.21 (0.1–0.55) to 0.14 (0.04–0.4) after 90 min, P < 0.001, and remained low thereafter, and the change at the end of the dialysis session was associated with percentage weight loss (r = −0.37, P = 0.003). Green and red pixel values did not change (predialysis 0.339 [0.333–0.345] to 0.302 [0.291–0.33] post, and 0.301 [0.293–0.328] predialysis to 0.339 [0.334–0.347] post, respectively). This pilot study showed that the maximum pulse wave amplitude measured in the external auditory meatus fell during the dialysis session, and that the fall was associated with fluid removal. This could potentially lead to the development of a monitoring device, which could fit in the ear and record during the dialysis session.

Keywords: blood flow; pilot study; auditory; external auditory; auditory meatus

Journal Title: Therapeutic Apheresis and Dialysis
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.