Advanced techniques have been described to remove embedded inferior vena cava (IVC) filters including the loop snare and modified loop snare (Hangman) techniques. Retrieval of embedded filters have been associated… Click to show full abstract
Advanced techniques have been described to remove embedded inferior vena cava (IVC) filters including the loop snare and modified loop snare (Hangman) techniques. Retrieval of embedded filters have been associated with higher rates of complications including IVC injury and stenosis. We report two challenging embedded retrievals complicated by IVC injury and haemorrhage. Haemostasis was successfully achieved with prolonged balloon tamponade, suggesting that injury to the IVC during filter retrieval may not need urgent surgery. However, both patients received short‐term complications related to caval thrombosis and patients in this cohort should be closely observed after retrieval. These cases support rigorous attention to filter indication and follow‐up.
               