LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Changes in transcranial near‐infrared spectroscopy values reflect changes in cardiac index during cardiac surgery

Photo from wikipedia

To determine whether changes in transcranial near‐infrared spectroscopy (NIRS) values reflect changes in cardiac index (CI) in adult cardiac surgical patients. Single‐center prospective post hoc analysis. University hospital. One hundred… Click to show full abstract

To determine whether changes in transcranial near‐infrared spectroscopy (NIRS) values reflect changes in cardiac index (CI) in adult cardiac surgical patients. Single‐center prospective post hoc analysis. University hospital. One hundred and twenty‐four adult patients undergoing cardiac surgery. In each patient, several CI measurements were taken, and NIRS values were collected simultaneously. We used a hierarchical linear regression model to assess the association between NIRS values and CI. We calculated a crude model with NIRS as the only factor included, and an adjusted model, where mean arterial pressure, end‐tidal CO2, and oxygen saturation were used as confounding factors. A total of 1301 pairs of NIRS and CI values were collected. The analysis of separate NIRS and CI pairs revealed a poor association, which was not statistically significant when adjusted with the chosen confounders. However, when the changes in NIRS from baseline or from the previous measurement were compared to those of CI, a clinically and statistically significant association between NIRS and CI was observed also in the adjusted model. Compared to the baseline and to the previous measurement, respectively, the regression coefficients with 95% confidence intervals were 0.048 (0.041–0.056) and 0.064 (0.055–0.073) in off‐pump coronary artery bypass patients and 0.022 (0.016–0.029) and 0.026 (0.020–0.033) in patients who underwent cardiopulmonary bypass. In an unselected cardiac surgical population, the changes in NIRS values reflect those in CI, especially in off‐pump coronary artery bypass patients. In this single‐center post hoc analysis of data from a prospectively collected database of cardiac surgery patients, paired measurements of cardiac output and NIRS revealed that while there was a no correlation between individual paired measurements, a small correlation was found in changes in the two measurements from baseline values. This highlights a potential to utilize changes in NIRS from baseline to suggest changes in cardiac output in cardiac surgical populations.

Keywords: nirs values; spectroscopy; values reflect; cardiac surgery; changes cardiac

Journal Title: Acta Anaesthesiologica Scandinavica
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.