A 70-year-old man underwent elective colonoscopy to investigate a positive faecal occult blood test result. Tight angulation in the sigmoid colon was found, and the adult colonoscope was changed to… Click to show full abstract
A 70-year-old man underwent elective colonoscopy to investigate a positive faecal occult blood test result. Tight angulation in the sigmoid colon was found, and the adult colonoscope was changed to a paediatric colonoscope, which allowed for the angulation to be passed gently. Visualization using the Olympus ScopeGuide 3D Navigation System [Olympus, VIC, Australia] demonstrated a reverse-alpha loop configuration, which could not be straightened. As there was still one-to-one forward progression, the colonoscopy was successfully completed to the caecum; however, on withdrawal, the loop could not be reduced and the colonoscope could not be withdrawn past 50 cm from the anal verge. Inspection of the patient’s groin revealed a large left-sided inguinoscrotal hernia containing a palpable colonoscope (Fig. 1). Attempts to manually reduce the hernia and withdraw the scope using gentle clockwise and anti-clockwise torsion were unsuccessful, even under a general anaesthetic with muscle relaxation. The patient underwent a midline laparotomy, which demonstrated a left-sided sliding inguinoscrotal hernia containing sigmoid colon and the loop of colonoscope. Subcutaneous tissue was mobilized off the anterior rectus sheath and external oblique aponeurosis on the left to allow a combined intra-abdominal and groin approach. The internal ring was enlarged by a lateral incision to aid reduction of the hernia. Structures of the spermatic cord were separated from the herniated colon, which was then reduced en masse by combined withdrawal of the colonoscope and manual pressure. The sigmoid colon was intact – a small serosal tear was repaired. There was no communication between the peritoneal cavity and a large left-sided hydrocele, which was confirmed on a post-operative ultrasound scan. Hernia repair was performed using synthetic mesh and the patient had an uneventful recovery. Incarceration of a colonoscope within an inguinal hernia is a rare complication of colonoscopy with about 15 case reports in the literature. It occurs most commonly on withdrawal but may also occur on insertion. The mechanics usually involve a hernia orifice that is wide enough to permit entry and exit of the colonoscope as well as looping, but is too small to allow full reduction of the loop and hence creates an obstruction on withdrawal. Multiple methods of management have been described, including manual reduction of the hernia, fluoroscopic-guided withdrawal of the scope and surgical hernia repair. Once non-operative approaches have failed, a surgical approach that allows adequate exposure of the inguinal region to assess for possible trauma and to facilitate safe enlarging of the hernia neck is required. The Olympus ScopeGuide 3D Navigation System is a magnetic endoscopic imaging system that consists of electromagnetic coils within the length of the colonoscope, which generate a pulsed emission of a low-intensity magnetic field. These are detected by a receiver dish placed near the patient’s abdomen, and the magnetic pulses are used to calculate and generate a real-time threedimensional image of the configuration of the colonoscope. Metaanalysis suggests that magnetic endoscopic imaging compared to standard colonoscopy may increase caecal intubation rates and shorten time to caecal intubation; however, it is not a widely available technology. It permits identification of loop formation during colonoscopy; however, it will not differentiate between a reducible or irreducible loop as this is based on tactile feedback on scope insertion and withdrawal. During colonoscopy in the left lateral position, the inguinal regions are not visible to the endoscopist. A history of inguinal hernia should be elicited before the procedure. To avoid incarceration Fig 1. Image depicts ScopeGuide picture superimposed on patient, with looped colonoscope within the hernia neck. Green dotted line indicates inguinal ligament.
               
Click one of the above tabs to view related content.