BACKGROUND Use of prolonged femoral intra-aortic balloon pump support limits the mobility of patients awaiting heart transplant. We assessed the safety and outcomes of a structured, tilting physical therapy protocol… Click to show full abstract
BACKGROUND Use of prolonged femoral intra-aortic balloon pump support limits the mobility of patients awaiting heart transplant. We assessed the safety and outcomes of a structured, tilting physical therapy protocol in patients supported by intra-aortic balloon pumps while awaiting transplant. METHODS We retrospectively reviewed five years of transplant patients. Eighteen patients received femoral intra-aortic balloon support, a heart transplant, and met all eligibility criteria. We compared complications and outcomes between patients who received the structured, tilting physical therapy (Protocol Group) and those that received standard of care (Control Group). RESULTS Complications were not significantly different between groups. The majority of the Protocol Group were discharged to home (10/12), while half (3/6) of the Control Group were discharged to a rehabilitation facility. Post-transplant length of stay was significantly less in the Protocol Group (median 16 vs 28 days, P = .03). CONCLUSION Despite the small number analyzed, the data indicates that the structured, tilting physical therapy protocol led to a significantly reduced length of stay post-transplantation. Importantly, use of the protocol did not result in access site complications, thrombosis or arrhythmias in the majority of the patients.
               
Click one of the above tabs to view related content.