LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Stability and Crestal Bone Behavior Following Simultaneous Placement of Multiple Dental Implants (Two or More) with the Bone Splitting Technique: A Clinical and Radiographic Evaluation

Photo from wikipedia

PURPOSE The present study aimed to measure the implant stability quotient (ISQ) values at three different time points after surgical procedures and crestal bone behavior in multiple implants (two or… Click to show full abstract

PURPOSE The present study aimed to measure the implant stability quotient (ISQ) values at three different time points after surgical procedures and crestal bone behavior in multiple implants (two or more) installed simultaneously with the bone splitting technique. MATERIALS AND METHODS For this study, 45 patients with different edentulous areas in the maxilla were selected, and a total of 114 dental implants were installed. Implant stability was measured by resonance frequency analysis immediately following implant placement to assess immediate stability (time 1) and stability at 90 days (time 2), and 150 days (time 3). Crestal bone height was measured in peri-apical radiographs at 90 and 150 days after implantation in relation to each implant shoulder, given that the implants were installed at the level of the crestal bone. RESULTS Six implants were not osseointegrated. Overall, the means and standard deviations of the ISQ values were 60.3 ± 4.94 (95% confidence interval [CI], 44-69) at baseline, 66.6 ± 5.28 (95% CI, 49-75) at 90 days, and 72.1 ± 4.28 (95% CI, 59-79) at 150 days (p < 0.0001). The mean marginal bone loss of the implants was 1.11 ± 0.61 mm on the mesial side and 1.17 ± 0.61 mm on the distal side at time 2, and 1.73 ± 0.68 mm on the mesial side and 1.79 ± 0.70 mm on the distal side at time 3. A strong positive correlation between implant stability and bone loss was detected (p < 0.0001). CONCLUSIONS Within the limits of this study, the bone splitting technique with simultaneous implant installation exhibited a good success rate with respect to the osseointegration index but requires attention with respect to crestal bone behavior.

Keywords: crestal bone; time; bone; bone behavior; stability; bone splitting

Journal Title: Clinical Implant Dentistry and Related Research
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.