LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Clinical and radiographic indices around narrow diameter implants placed in different glycemic-level patients.

Photo by papaioannou_kostas from unsplash

BACKGROUND Studies assessing peri-implant clinical and marginal bone resorption (MBR) around narrow diameter implants (NDIs) placed in different glycemic levels are uninvestigated. OBJECTIVE The present 3-year retrospective follow-up investigation was… Click to show full abstract

BACKGROUND Studies assessing peri-implant clinical and marginal bone resorption (MBR) around narrow diameter implants (NDIs) placed in different glycemic levels are uninvestigated. OBJECTIVE The present 3-year retrospective follow-up investigation was designed to explore clinical and radiographic status of NDIs placed in individuals with different glycemic control levels. MATERIALS AND METHODS Patients with serum hemoglobin A1c (HbA1c) levels ≥6.5% (Group-1), 5.7%-6.4% (Group-2), and 4.0%-5.0% (Group-3) were included. Clinical indices evaluating bleeding on probing (BOP), plaque scores (PI), peri-implant probing depth (PD), and MBR were recorded around NDIs at 1-, 2-, and 3-year follow-up. Serum HbA1c test was carried out for all patients to assess the profile of glycosylated hemoglobin at 1 and 3 years of follow-up. RESULTS A significant reduction in mean HbA1c levels from year 1 to year 3 follow-up period was seen in Group-1 only. PI varied from 0.40 in Group 1 at 2 year and 0.42 at 3-year follow-up to 0.18 at 2-year (P = 0.032) and 0.17 at 3-year (P = 0.018) follow-up, respectively. Greater BOP was noted in Group 1 (0.53) as compared with Group 2 (0.42) and Group 3 (0.21) (P = 0.048) at 3-year follow-up. PD after 3 year ranged from 2.04 mm in Group 3 to 2.32 mm in Group 1 that showed statistically significant difference (P = 0.037). No statistical significant differences were observed in MBR at any time point between the groups. CONCLUSION The results of this short-term follow-up study indicate that NDIs show clinical and radiographic stability, provided oral cleanliness and glycemic levels are relatively maintained. Further long-term clinical studies are needed to evaluate implant stability over the period along with controlled glycemic status.

Keywords: clinical radiographic; year; group; different glycemic; narrow diameter; around narrow

Journal Title: Clinical implant dentistry and related research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.