LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Monolithic zirconia single tooth implant-supported restorations with CAD/CAM titanium abutments in the posterior region: A 1-year prospective case series study.

Photo from wikipedia

PURPOSE To assess the clinical, radiographic, and patient-reported outcome measures, including the success of screw-retained monolithic zirconia implant-supported restorations with CAD/CAM titanium abutments in the posterior region during a 1-year… Click to show full abstract

PURPOSE To assess the clinical, radiographic, and patient-reported outcome measures, including the success of screw-retained monolithic zirconia implant-supported restorations with CAD/CAM titanium abutments in the posterior region during a 1-year follow-up. METHODS In a prospective case series, 50 molar sites in the posterior region of 46 patients with a minimum age of 18 years and sufficient bone volume and anatomical conditions for placing an implant (≥8 mm) and an anatomical restoration were included. Parallel-walled implants with a conical connection were inserted in a two-stage surgical procedure. Implant uncovering and healing abutment placement occurred 12 weeks after insertion. Two weeks after mucosa healing, a screw-retained monolithic zirconia restoration with a CAD/CAM titanium abutment was placed. Clinical, radiographic, and patient-reported outcome measures were collected at baseline before implant placement and then during the 1 month and 1 year follow-ups. RESULTS At the 1 year follow-up, 49 restorations could be evaluated. The plaque accumulation, presence of calculus, bleeding tendency and peri-implant inflammation indices were low, representing healthy peri-implant conditions. The mean marginal bone level change between the 1 month and the 1 year follow-up was -0.17 ± 0.46 mm. The mean patient satisfaction was high. The restoration success was, according to the modified USPHS criteria, 95.9%. CONCLUSION Monolithic zirconia implant-supported restorations with CAD/CAM titanium abutments have very good clinical, radiographic and patient-reported outcomes after 1 year in function.

Keywords: cam titanium; year; cad cam; monolithic zirconia

Journal Title: Clinical implant dentistry and related research
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.