LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Within-patient evaluation of chewing efficiency and maximum bite force of conventional dentures, fixed prostheses, and milled bar overdentures used for All-on-4 implant rehabilitation of atrophied mandibular ridges: A short-term randomized trial.

Photo from wikipedia

PURPOSE This crossover study aimed to evaluate chewing efficiency and maximum bite force (BF) of conventional dentures, fixed prostheses, and milled bar overdentures (MO) used for All-on-4 implant rehabilitation of… Click to show full abstract

PURPOSE This crossover study aimed to evaluate chewing efficiency and maximum bite force (BF) of conventional dentures, fixed prostheses, and milled bar overdentures (MO) used for All-on-4 implant rehabilitation of atrophied mandibular ridges. METHODS Sixteen edentulous participants with resorbed mandibular ridges received new conventional dentures (CD, control). Four implants were inserted after 3 months in the mandible using the All-on-4 protocol and loaded immediately with acrylic prosthesis. In a crossover manner, each patient had either fixed restoration (FR, 12 occlusal units) or MO (14 occlusal units) randomly in a crossover study design. Chewing efficiency was evaluated using the mixing ability test. The hue deviation (HD) of two-colored gum was calculated after being chewed for 5, 10, 20, 30, and 50 masticatory cycles. Maximum BF was evaluated using a BF device. HD and BF were measured after using CD, FR, and MO prostheses. RESULTS For all groups, the highest HD (i.e., the lowest chewing efficiency) was noted with 5 strokes, followed by 10, 20, 30 strokes, and the lowest HD (i.e., the highest chewing efficiency) was noted with 50 strokes. For all number of chewing strokes, CD showed the highest HD, then FR, and MO recorded the lowest HD. The highest BF was observed with MO, then FR, and the lowest BF was noted with CD. CONCLUSION Within the limitations of this short-term investigation, both FR and MO used for All-on-4 implant rehabilitation of patients with resorbed mandibular ridges improve masticatory efficiency and maximum BFs compared to CD. However, MO was associated with significantly higher chewing efficiency and maximum BFs than fixed prosthesis.

Keywords: mandibular ridges; efficiency; efficiency maximum; used implant; chewing efficiency; conventional dentures

Journal Title: Clinical implant dentistry and related research
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.