A 38‐year‐old woman with peripartum cardiomyopathy underwent placement of a HeartMate 3 (HM3) left ventricular assist device (LVAD). Postoperatively, she refused warfarin therapy and was maintained on aspirin monotherapy for… Click to show full abstract
A 38‐year‐old woman with peripartum cardiomyopathy underwent placement of a HeartMate 3 (HM3) left ventricular assist device (LVAD). Postoperatively, she refused warfarin therapy and was maintained on aspirin monotherapy for 19 months. She did not experience thrombotic or thromboembolic complications associated with lack of oral vitamin K antagonist anticoagulation. Our patient represents the longest reported duration of a patient with HM3 LVAD maintained without warfarin without evidence of thrombotic or thromboembolic events.
               