Red cell clumping in stem cell collection bag

Photo from wikipedia

A 67-year-old male with diffuse large B-cell lymphoma (DLBCL) underwent a 4-hour apheresis collection of peripheral blood stem cells (PBSC). The flow rate was maintained at 60 mL/minute, and a… Click to show full abstract

A 67-year-old male with diffuse large B-cell lymphoma (DLBCL) underwent a 4-hour apheresis collection of peripheral blood stem cells (PBSC). The flow rate was maintained at 60 mL/minute, and a total volume of 12.6 L was processed. A blood warmer was used. The collection was unremarkable, and no abnormality was noted upon repeated visual inspections of the collection bag throughout the procedure and upon completion. The bag was then placed in a 4°C refrigerator. Approximately

Keywords: red cell; stem; collection; cell; collection bag