LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of a viscoelastic point-of-care coagulation monitor with thromboelastography in sick dogs with hemostatic abnormalities.

Photo from wikipedia

BACKGROUND Viscoelastic coagulation monitor (VCM-Vet) is a point-of-care device that has been used to characterize hemostatic abnormalities in sick pets but has not been validated in veterinary patients. OBJECTIVES We… Click to show full abstract

BACKGROUND Viscoelastic coagulation monitor (VCM-Vet) is a point-of-care device that has been used to characterize hemostatic abnormalities in sick pets but has not been validated in veterinary patients. OBJECTIVES We aimed to compare VCM-Vet and thromboelastography (TEG) in sick dogs with suspected disorders of hemostasis. METHODS Duplicate VCM-Vet tests using untreated native blood performed concurrently on two VCM-Vet machines, and simultaneous TEG tests were performed (one citrated native (CN), and one activated with tissue factor (TF) at a 1:3600 dilution). Each VCM-Vet result was compared with both TF-activated and CN TEG. RESULTS Fifty-three dogs were enrolled. Eleven cases displayed apparent hyperfibrinolysis. Spearman correlation coefficients for individual VCM-Vet devices and CN and TF TEG were obtained between R and CT values and ranged from 0.21 to 0.27, CFT and K (r = 0.60-0.67), angles (r = 0.51-0.62), and MCF and MA (r = 0.85-0.87). Comparison of the two VCM-Vet devices displayed positive correlations for all clot formation parameters with Lin's concordance correlation coefficients of 0.75-0.95. Variable lysis parameter agreement existed between the VCM-Vet devices and VCM-Vet and TEG. When samples were classified as hypercoagulable or coagulopathic, VCM-Vet had a low positive predictive value (17-33%) for the detection of hypercoagulable states and a moderate negative predictive value (64-74%) for the detection of coagulopathy as defined by TEG. CONCLUSIONS VCM-Vet and TEG had variable correlations in clot formation values and a strong correlation for final clot strength. More information is needed to make conclusions about the lysis parameters. Artifact in the fibrinolysis portion of the test can confound the interpretation of VCM-Vet results.

Keywords: point care; vet; coagulation monitor; vcm vet; hemostatic abnormalities

Journal Title: Veterinary clinical pathology
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.