LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of point-of-care NOVA CCX blood gas analyzer to laboratory analyzer in a population of healthy adult cats.

Photo by cravethebenefits from unsplash

OBJECTIVE To compare the level of agreement of measurement of analytes (sodium, chloride, potassium, urea nitrogen [UN], creatinine, glucose) in a population of healthy adult cats between the point-of-care (POC)… Click to show full abstract

OBJECTIVE To compare the level of agreement of measurement of analytes (sodium, chloride, potassium, urea nitrogen [UN], creatinine, glucose) in a population of healthy adult cats between the point-of-care (POC) analyzer and laboratory analyzer. To establish reference intervals for the POC analyzer in healthy adult cats. DESIGN Prospective observational study. SETTING University teaching hospital. ANIMALS Fifty-five cats were screened. Seven cats were excluded due to aggression that prohibited phlebotomy, and 1 cat was excluded due to prolonged restraint; 47 cats were enrolled. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS In this patient population, reference intervals for the POC analyzer were calculated: sodium 145-157 mmol/L; chloride 116-124 mmol/L; potassium 3.4-5.5 mmol/L; UN 5.71-13.9 mmol/L (16-39 mg/dl); creatinine 74.3-189.2 mmol/L (0.84-2.14 mg/dl); and glucose 4-11.8 mmol/L (72-213 mg/dl). Comparison between the POC analyzer and laboratory analyzer using the Bland-Altman method was performed. The bias for each analyte is as follows: sodium 1.55 mmol/L; chloride 0.99 mmol/L; potassium 0.21 mmol/L; UN -0.25 mmol/L (-0.7 mg/dl); creatinine 9.73 mmol/L (0.11 mg/dl); and glucose 0.5 mmol/L (9.79 mg/dl). CONCLUSIONS Reference intervals for each analyte were similar to other chemistry analyzers. There was no significant difference between the POC and laboratory analyzers in analysis of UN, with a statistically significant difference observed with sodium, potassium, chloride, creatinine, and glucose. However, the values are likely not sufficiently different to alter initial clinical decisions regarding patient care.

Keywords: analyzer laboratory; mmol; healthy adult; care; analyzer; adult cats

Journal Title: Journal of veterinary emergency and critical care
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.