LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Anterior segment parameters in normal dogs using the Pentacam® HR Scheimpflug system.

Photo by charlesdeluvio from unsplash

OBJECTIVE To describe and compare normative anterior segment parameters between canine age groups using the Pentacam® HR Scheimpflug camera (Pentacam). ANIMALS STUDIED Thirty-six sedated dogs (60 eyes) of varying ages… Click to show full abstract

OBJECTIVE To describe and compare normative anterior segment parameters between canine age groups using the Pentacam® HR Scheimpflug camera (Pentacam). ANIMALS STUDIED Thirty-six sedated dogs (60 eyes) of varying ages and breeds were imaged with the Pentacam; only nondiseased anterior segments were included. PROCEDURES Dogs were divided into three age groups: Group 1 (1-5 years), Group 2 (6-10 years), and Group 3 (11-15 years). Values assessed included central corneal thickness (CCT), anterior and posterior corneal elevation (ACE/PCE), anterior and posterior corneal curvature metrics, corneal volume (CV), anterior and posterior corneal astigmatism (AA/PA), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA). Tukey-adjusted pairwise comparisons were performed. RESULTS Overall CCT (mean ± SD) was 631.07 ± 59.91 µm. Central corneal thickness was 608.60 ± 48.63 µm for Group 1, 648.57 ± 51.06 µm for Group 2, and 635.37 ± 73.71 µm for Group 3. Anterior corneal elevation (ACE) measured 9.08 ± 0.58 mm, PCE measured 8.04 ± 0.50 mm, and CV was 58.13 ± 5.39 mm3 . Astigmatism values were 1.34 ± 0.94 D for AA and 0.46 ± 0.44 D for PA. Anterior chamber values were 3.76 ± 0.56 mm for ACD, 383.68 ± 66.24 mm3 for ACV, and 23.62 ± 29.33˚ for ACA. Significant differences were found between Groups 1 and 2 for CV (55.08 ± 4.08 mm3 and 60.32 ± 4.19 mm3 , respectively), (P = 0.02). CONCLUSIONS Corneal volume significantly increased between Group 1 and Group 2. Central corneal thickness increased from Group 1 to Group 3, but was not significant with the current sample size. There were no other differences between age groups.

Keywords: segment parameters; corneal; pentacam scheimpflug; anterior segment; group; using pentacam

Journal Title: Veterinary ophthalmology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.