LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy.

Photo from wikipedia

OBJECTIVE To determine corneal thickness (CT) and axial anterior chamber depth (ACD) using ultrasound biomicroscopy (UBM) in normal adult horses. To compare corneal thickness measurements between UBM and ultrasonic pachymetry.… Click to show full abstract

OBJECTIVE To determine corneal thickness (CT) and axial anterior chamber depth (ACD) using ultrasound biomicroscopy (UBM) in normal adult horses. To compare corneal thickness measurements between UBM and ultrasonic pachymetry. ANIMALS STUDIED Sixty eyes of 30 healthy adult horses aged 8-24 years. PROCEDURES Ultrasonic pachymetry (velocity of 1640 m/s) was utilized to obtain measurements of the central, superior, temporal, inferior, and nasal cornea. Triplicate images of the same corneal locations were acquired using UBM (50 MHz). Images of the axial anterior chamber were used to measure ACD. Intraocular pressure (IOP) was estimated using rebound tonometry, and axial globe length was measured using ultrasonographic biometry. RESULTS CT (mean ± SD µm) measured by UBM was 854 ± 61 (central), 994 ± 58 (superior), 930 ± 57 (temporal), 979 ± 55 (inferior), and 898 ± 48 (nasal). CT measured by UBM was greater than that measured by ultrasonic pachymetry at all locations and was statistically significant at all locations except inferior (p = 0.0006-0.048). No sex nor age effect was detected for CT at any location. The repeatability of ultrasonic pachymetry was superior to that of UBM. Mean ± SD ACD was 5.74 ± 0.41 mm. A weak positive correlation was identified between central CT and IOP and between central CT and axial globe length. CONCLUSIONS Normal data for CT and ACD of the adult horse obtained using UBM are provided. CT determined by UBM was greater relative to pachymetry at all corneal locations.

Keywords: corneal thickness; pachymetry; adult; anterior chamber

Journal Title: Veterinary ophthalmology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.