LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Accuracy of a patient‐specific 3D printed drill guide for placement of cervical transpedicular screws

Photo by tomspentys from unsplash

OBJECTIVE To develop a patient-specific 3-dimensional (3D) printed drill guide for placement of cervical transpedicular screws and to assess its accuracy. STUDY DESIGN Prospective case-series. SAMPLE POPULATION Thirty-two cervical pedicle… Click to show full abstract

OBJECTIVE To develop a patient-specific 3-dimensional (3D) printed drill guide for placement of cervical transpedicular screws and to assess its accuracy. STUDY DESIGN Prospective case-series. SAMPLE POPULATION Thirty-two cervical pedicle screws (CPS) placed in 3 large breed dogs. METHODS Computed tomographic (CT) data of the cervical vertebrae were exported to a medical image processing software and 3D virtual vertebral models were created for each vertebra. These models were processed in a computer aided design (CAD) software to determine the optimal trajectory and size of the CPS. Virtual drill guides were created for each patient, 3D-printed, and used intraoperatively. Locking titanium screw heads were bonded with polymethylmethacrylate cement to stabilize affected vertebral segments. Postoperative CT was used to assess the radiological accuracy of CPS placement in each dog. For each screw, CAD files were analyzed to determine a screw-diameter-to-pedicle-width-ratio (SDPWR) at the narrowest point of the pedicle. RESULTS A total of 32 CPS were placed, measuring 3.5 mm (n = 20), 2.7 mm (n = 11), and 2.4 mm (n = 1) in diameter. The majority (29/32) of these screws were placed without evidence of vertebral canal breach (grade 0), whereas a vertebral canal breach <2 mm (grade 1) was detected in 3/32 screws. This outcome was achieved despite a mean SDPWR of 0.75 (range 0.58-0.93). CONCLUSION The use of a 3D-printed patient-specific drill guide permitted accurate placement of 32 bicortical pedicle screws in the caudal cervical vertebrae of 3 dogs. This technique may improve clinical outcome through superior biomechanical properties of screws, reduced surgical time, and reduced morbidity. These results warrant evaluation of patient outcome in a larger population.

Keywords: patient specific; accuracy; placement; printed drill; drill guide; patient

Journal Title: Veterinary Surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.