Varying aspect ratio (AR) channels are found in modern gas turbine airfoils for internal cooling purposes. Corresponding experimental data are needed in understanding and assisting the design of advanced cooling… Click to show full abstract
Varying aspect ratio (AR) channels are found in modern gas turbine airfoils for internal cooling purposes. Corresponding experimental data are needed in understanding and assisting the design of advanced cooling systems. The present study features a two-pass rectangular channel with an AR = 4:1 in the first pass with the radial outward flow and an AR = 2:1 in the second pass with the radial inward flow after a 180 deg tip turn. Effects of rib coverage near the tip region are investigated using profiled 45 deg ribs (P/e = 10, e/Dh ≈ 0.11, parallel and in-line) with three different configurations: less coverage, medium coverage, and full coverage. The Reynolds number (Re) ranges from 10,000 to 70,000 in the first passage. The highest rotation number achieved was Ro = 0.39 in the first passage and 0.16 in the second passage. Heat transfer coefficients on the internal surfaces were obtained by the regionally averaged copper plate method. The results showed that the rotation effects on both heat transfer and pressure loss coefficient are reduced with an increased rib coverage in the tip turn region. Different rib coverage upstream of the tip turn significantly changes the heat transfer in the turn portion. Heat transfer reduction (up to −27%) on the tip wall was seen at lower Ro. Dependence on the Reynolds number can be seen for this particular design. The combined geometric, rib coverage, and rotation effects should be taken into consideration in the internal cooling design.
               
Click one of the above tabs to view related content.