LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A Comparison of Physiological Response to Incremental Testing on Stationary and Dynamic Rowing Ergometers.

PURPOSE The purpose of the current study was to compare responses to graded exercise testing (GXT) on 2 popular commercial rowing ergometers. METHODS A cohort of 23 subelite male rowers… Click to show full abstract

PURPOSE The purpose of the current study was to compare responses to graded exercise testing (GXT) on 2 popular commercial rowing ergometers. METHODS A cohort of 23 subelite male rowers (age 20 [2] y, height 1.88 [0.06] m, body mass 82.0 [8.8] kg) performed a GXT on both stationary (Concept2 [C2]) and dynamic (RowPerfect3 [RP3]) rowing ergometers. Physiological responses including oxygen consumption (VO2), heart rate (HR), blood lactate concentration (BLa), stroke rate (SR), and minute ventilation (VE) were recorded. BLa data were plotted graphically and anaerobic threshold was identified using the Dmax method. Workload, HR, and VO2 at Dmax were interpolated. Physiological responses at maximal exercise and at Dmax were compared, along with response across a discrete range of submaximal workloads. RESULTS At maximal exercise, no significant differences in HR, VO2, or BLa were observed (P > .05); however, VEpeak was significantly higher during RP3 tests (T = 2.943, P < .05). No significant differences in HR, VO2, or BLa at Dmax were observed (P > .05). When comparing across submaximal workloads, HR was significantly higher with the RP3 at 2 distinct workloads (210 and 240 W; P < .05), while SR was higher during RP3 testing at all workloads (F = 56.7, P < .05). When SR was fixed as a covariate, the effect of ergometer on HR response was not significant. A significant workload by ergometer interaction effect was observed for SR with higher data recorded on the RP3 (F = 3.48, P < .01). Levels of agreement for GXT-derived measures of anaerobic threshold (Dmax) were deemed unacceptable. CONCLUSIONS These results indicate that while some differences in HR and VE response were observed between ergometers, these differences were a result of SR alterations between ergometer type. While no differences in response at Dmax were observed, the poor levels of agreement between ergometers suggests that prescription of GXT-derived threshold for training should ideally be specific to the rowing ergometer upon which the test was performed.

Keywords: comparison physiological; dmax; response; higher rp3; rowing ergometers

Journal Title: International journal of sports physiology and performance
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.