Interchangeability and reliability of macular perfusion parameter measurements using optical coherence tomography angiography

Photo by wtrsnvc from unsplash

Aim The aim of the study was to investigate the interchangeability and reliability of macular perfusion measurements using optical coherence tomography angiography. Methods A prospective cross-sectional observational study. Healthy adult… Click to show full abstract

Aim The aim of the study was to investigate the interchangeability and reliability of macular perfusion measurements using optical coherence tomography angiography. Methods A prospective cross-sectional observational study. Healthy adult Chinese subjects were recruited. Macular perfusion parameters were automatically analysed by software included in a spectral-domain optical coherence tomography system. The vessel density (VD) of the whole, parafovea, superior-hemi, inferior-hemi, fovea, temporal, superior, nasal and inferior quadrants as well as the foveal avascular zone (FAZ) and choroidal capillary VD (CCVD) were quantified. Results A total of 51 eyes in 27 subjects were included (8 men and 19 women, mean age 24±4 years). Significant differences in VD of all quadrants (all p<0.001) was detected between the 3×3 mm and 6×6 mm macular scan size. The biggest difference of VD between the two scan size was 5.14±4.03, which was not clinically meaningful. No statistically significant differences were found in FAZ or CCVD between the two different scan sizes. The mean intraclass correlation coefficient (ICC) between two measurements from the inter-rater of 20 eyes was from 0.560 to 0.893 for VD and 0.845 for FAZ. The mean ICC between two measurements from the intrarater of 20 eyes was from 0.497 to 0.870 for VD and 0.780 for FAZ. Conclusions FAZ and CCVD are interchangeable between the 3×3 mm and 6×6 mm macular scan sizes. The VD differences between the two different scan sizes are not clinically meaningful. The macular perfusion parameters presented good but not perfect reliability, which should be acknowledged in clinical practice.

Keywords: optical coherence; perfusion; macular perfusion; coherence tomography; reliability

Journal Title: British Journal of Ophthalmology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.