LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Lysis Timer: a new sensitive tool to diagnose hyperfibrinolysis in liver transplantation

Photo by hudsoncrafted from unsplash

Aims Diagnosis of hyperfibrinolysis in orthotopic liver transplantation (OLT) remains challenging. Euglobulin clot lysis time (ECLT) is not adapted to clinical situations. ROTEM is specific but seldom sensitive to hyperfibrinolysis.… Click to show full abstract

Aims Diagnosis of hyperfibrinolysis in orthotopic liver transplantation (OLT) remains challenging. Euglobulin clot lysis time (ECLT) is not adapted to clinical situations. ROTEM is specific but seldom sensitive to hyperfibrinolysis. The Lysis Timer assesses ‘Global Fibrinolytic Capacity’ in citrated plasma (GFC/LT). GFC/LT associates reagents for in vitro triggering of the clot (thrombin and calcium) and its lysis (tissue-plasminogenactivator (t-PA)), turbidity signal acquisition by the Lysis Timer, and dedicated software converting the digital signal into an optical curve. A visual check of the curves was systematic to ascertain the lysis time values calculated by the software. The primary aim of this prospective observational study was to evaluate the ability of GFC/LT to recognise hyperfibrinolysis during OLT. The secondary aim was to compare its results with ROTEM maximum lysis (EXTEM ML) and with standard laboratory tests. Methods Thirty consecutive adult patients undergoing OLT were included (NCT03012633). Standard laboratory tests, ROTEM, GFC/LT, ECLT and fibrinolysis parameters were assayed at five sample times. Results GFC/LT was correlated with ECLT, plasmin activator inhibitor 1 antigen and activity and t-PA activity (r=0.490, 0.681, 0.643 and –0.359, respectively). Hyperfibrinolysis was defined as ECLT ≤60 min. Receiver operating characteristic curve analysis showed that GFC/LT with a threshold of 31 min detected hyperfibrinolysis with a sensitivity of 0.88 (95% CI 0.73 to 0.96), a specificity of 0.68 (95% CI 0.56 to 0.78) and an area under the curve (AUC) of 0.85 (95% CI 0.74 to 0.94). EXTEM ML >12% did not detect hyperfibrinolysis (sensitivity 0.38 (95% CI 0.24 to 0.55), specificity 0.95 (95% CI 0.86 to 0.99) and AUC 0.60 (95% CI 0.46 to 0.75)). Conclusions GFC/LT recognised hyperfibrinolysis during OLT with a significant agreement with the other tests of fibrinolysis. Trial registration number NCT03012633.

Keywords: lysis; liver transplantation; lysis timer; hyperfibrinolysis

Journal Title: Journal of Clinical Pathology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.