LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparing a novel Catfish flow restoration device and the Solitaire stent retriever for thrombectomy revascularisation in emergent largevessel occlusion stroke: a prospective randomised controlled study

Photo by kellysikkema from unsplash

Background The Catfish stent retriever is a newly developed mechanical thrombectomy device for rapid recanalisation in emergent large vessel occlusion (ELVO) stroke. The current trial aimed to assess whether the… Click to show full abstract

Background The Catfish stent retriever is a newly developed mechanical thrombectomy device for rapid recanalisation in emergent large vessel occlusion (ELVO) stroke. The current trial aimed to assess whether the Catfish stent retriever is non-inferior to the Solitaire stent retriever in terms of outcomes in ELVO stroke. Methods This was a randomised, prospective, parallel-group, multicentre, open-label, non-inferiority study conducted at 18 sites in China. The primary outcome was the proportion of cases with successful recanalisation (modified thrombolysis in cerebral infarction score of 2b or 3) following the procedure. Secondary efficacy outcomes included the National Institutes of Health Stroke Scale scores at 24 hours and 7 days or discharge if earlier, time from artery puncture to successful recanalisation and good clinical outcome (modified Rankin scale score ≤2) at 90 days. Safety outcomes included symptomatic intracranial haemorrhage, all cause-death and severe adverse events at 90 days. Results Between 3 March 2019 and 5 June 2021, 118 and 120 patients were randomly allocated to the Catfish and Solitaire groups, respectively. The primary endpoint after all endovascular procedures was non-inferior in the Catfish group (88.5%, 100/113) than in the Solitaire group (87.7%, 100/114), with a rate difference (RD) of 0.78% (95% CI –7.64 to –9.20; p=0.001). Sensitivity analysis only considering the per-protocol set also yielded similar results, with an RD of 0.83% (95% CI –7.03 to –8.70; p<0.001). Additionally, the proportions of cases with good clinical outcomes (47.8% vs 50.0%, p=0.739) and all-cause death rates (17.7% vs 18.8%, p=0.700) were similar in both groups at 90 days. Conclusions The Catfish stent retriever is an effective and safe device for endovascular recanalisation in ELVO stroke. Trial registration number NCT03820882.

Keywords: solitaire stent; stent; device; stent retriever

Journal Title: Stroke and Vascular Neurology
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.