LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Combined use of multiple external and internal standards in LA-ICP-MS analysis of bulk geological samples using lithium borate fused glass

Photo from wikipedia

We describe a method for LA-ICP-MS elemental analysis of geological materials using low-dilution Li-borate fused glass WDXRF pellets, with samples, drift monitor, and 18 reference materials (RMs) identically prepared. After… Click to show full abstract

We describe a method for LA-ICP-MS elemental analysis of geological materials using low-dilution Li-borate fused glass WDXRF pellets, with samples, drift monitor, and 18 reference materials (RMs) identically prepared. After analysis for 46 elements by WDXRF, LA-ICP-MS intensities from samples and RMs are collected, and background corrected with Iolite software. HALite , a new software application, was developed to derive the elemental compositions from the LA-ICP-MS net signals. In HALite , elements are drift corrected using polynomial functions, and flux-fused RM element sensitivities are calculated from known mass fractions. Multiple internal standard (IS) elements are used to model each sample's laser response. Analyte mass fractions in unknowns are determined using the calibrated sensitivity correlation models for multiple IS elements. Either the WDXRF mass fractions or the initial round of calculated LA-ICP-MS mass fractions are used to calculate weighted mean sensitivities. Validation experiments with flux-fused RMs run as unknowns yield results with less than 5-10% total relative uncertainty for most analytes. We derive equations which allow calculation of the precision and total uncertainty as a function of mass fraction for each analyte element. Supplementary materials: Table 1 - RMs used; Table 2 - Operating parameters; Table 3 - Model vs. accepted mass fractions; Table 4 - NIST 610 vs. multiple IS models; Table 5 - Fitting parameters; Appendix 1 - HALite description; Appendix A - Summary calibration graphs; Appendix B - Validation results; Appendix C - WDXRF comparisons; Appendix D - Repeatability uncertainties; Appendix E - RM uncertainties; Appendix F - Total uncertainties for this article are available at https://doi.org/10.6084/m9.figshare.c.6639885

Keywords: analysis; mass fractions; fused glass; borate fused

Journal Title: Geochemistry: Exploration, Environment, Analysis
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.