LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

10-Year Results of Standard Cross-Linking in Patients with Progressive Keratoconus in Romania

Photo from wikipedia

Purpose The purpose of the current study was to evaluate the long-term functional results based on keratometric measurements, spherical and cylinder equivalent in patients with progressive keratoconus treated with conventional… Click to show full abstract

Purpose The purpose of the current study was to evaluate the long-term functional results based on keratometric measurements, spherical and cylinder equivalent in patients with progressive keratoconus treated with conventional “epi-off” corneal collagen cross-linking (CXL). Methods We conducted a retrospective study in which 113 eyes from 90 keratoconus-treated patients with CXL between 2006 and 2008 in Oculens Eye Clinic from Cluj-Napoca, Romania, were included. The diagnosis of keratoconus was based on corneal topography and its clinical signs. All patients were evaluated preoperatively, and a follow-up was performed at 1, 3, and 6 months and every year from 1 to 10 years after conventional CXL. Results All keratometry measurements improved significantly during the follow-up. Compared to preoperative values, the improvement of Kmax become statistically significant at 1 year after CXL (mean change compared to baseline −0.9 D, p < 0.001) and remained statistically significant thereafter up to 10 years (mean change compared to baseline −2.3 D, p < 0.001). As compared to preoperative values, mean spherical equivalent and mean cylinder improved during the follow-up, from a mean of −6.22 D before CXL to a mean value of −5.0 at 10 years, following CXL for spherical equivalent and from −4.4 D at baseline to −3.4 D at 10 years for cylinder (p < 0.05 for both). Uncorrected visual acuity increased, remaining statistically significant, by 0.104 logMAR at 10 years after CXL (p=0.0015), and best-corrected visual acuity increased by 0.135 logMAR at 10 years after CXL (p=0.015). We did not observe any case of severe complication. Conclusion Our results show that CXL has a favorable effect on the progression of KC. The reduced K values, cylinder and spherical equivalent, and increased visual acuity remained the same 10 years after the procedure.

Keywords: patients progressive; spherical equivalent; year; progressive keratoconus; cross linking; statistically significant

Journal Title: Journal of Ophthalmology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.