LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Results of the Pinhole Test Correlate with Hybrid Contact Lens Visual Acuity in Patients with Visual Impairment due to Corneal Diseases

Introduction Trial rigid lens fitting is considered the best approach to determine whether the correction of residual defocus and irregular astigmatism might improve the visual acuity in patients with corneal… Click to show full abstract

Introduction Trial rigid lens fitting is considered the best approach to determine whether the correction of residual defocus and irregular astigmatism might improve the visual acuity in patients with corneal disorders including keratoconus. This study aimed to analyze the correlation between hybrid lenses and pinhole visual acuity (VA). Methods Patients undergoing hybrid contact lens fitting at the Hygeia Clinic, Poland, were included. The VA of each patient was assessed as decimal Snellen fractions under the following conditions: (i) uncorrected VA, (ii) VA with spherocylindrical correction (i.e., corrected distance VA), (iii) VA with a single 1.2 mm pinhole occluder, and (iv) VA with the best-fitted hybrid contact lens. Pearson's correlation coefficient r was used to assess correlations among variables. Results This study involved 29 eyes of 19 patients, mainly with advanced keratoconus. The uncorrected VA was 0.11 ± 0.10. The pinhole test provided significantly improved VA over corrected distance VA (0.51 ± 0.29 vs. 0.31 ± 0.20, respectively; p < 0.0001). Similarly, the fitted hybrid contact lenses provided improved VA over corrected distance VA (0.66 ± 0.26 vs. 0.31 ± 0.20, respectively; p < 0.0001). The pinhole VA was strongly correlated with the hybrid contact lens VA (r = 0.8135; 95% CI: 0.61–0.92; p < 0.0001). The improvement in the pinhole test over corrected distance VA was moderately correlated with the improvement with the fitted lens over corrected distance VA (r = 0.6269; 95% confidence interval (CI): 0.32–0.80; p=0.0005). Conclusions A significant improvement in VA with the pinhole test is a simple predictor of general improvement with hybrid contact lenses. The pinhole test should be used in patients with corneal diseases such as keratoconus to determine whether optical aberrations associated with the disease cause their visual impairment.

Keywords: contact; pinhole test; contact lens; hybrid contact; visual acuity

Journal Title: Journal of Ophthalmology
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.