LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Reproducibility of Foveal Avascular Zone and Superficial Macular Retinal Vasculature Measurements in Healthy Eyes Determined by Two Different Scanning Protocols of Optical Coherence Tomography Angiography

Photo by nagaranbasaran from unsplash

Purpose: To assess the reproducibility of quantitative measurements of the foveal avascular zone (FAZ) and retinal vasculature determined by different scanning protocols of optical coherence tomography angiography (OCTA) in healthy… Click to show full abstract

Purpose: To assess the reproducibility of quantitative measurements of the foveal avascular zone (FAZ) and retinal vasculature determined by different scanning protocols of optical coherence tomography angiography (OCTA) in healthy volunteers. Method: All participants were scanned by two trained operators using an AngioPlex OCTA. Both angiography protocols (6 × 6 mm and 3 × 3 mm) were performed three times on the same eye by operator A and one additional time by operator B. The FAZ area and perimeter, retinal vessel length density (VLD) and perfusion density (PD) of different regions were analysed. Results: Fifty-two eyes from 52 subjects were recruited for this study. The repeated measurements of FAZ, VLD, and PD parameters obtained by the same operator, as well as by different operators, were not significantly different when the same protocol was used (p > 0.05). The intra- and inter-operator intraclass correlation coefficients (ICCs) of the FAZ and central VLD and PD parameters (range, 0.99–0.95) were better than the intra- and inter-operator ICCs of VLD and PD in the inner and outer rings (range, 0.86–0.90). The FAZ area, perimeter, and VLDs obtained by the 3 × 3 mm protocol were larger than those obtained by the 6 × 6 mm protocol (p < 0.01), but the PDs obtained by the 3 × 3 mm protocol were smaller than those obtained by the 6 × 6 mm protocol (p < 0.001). All of the corresponding parameters obtained by the two protocols were positively correlated (r = 0.64–0.99, p < 0.001). Conclusion: Both the 6 × 6 and 3 × 3 mm protocols of the AngioPlex OCTA provide good reproducibility for assessing the FAZ and superficial retinal vasculature. However, the values obtained by these different protocols cannot be compared directly.

Keywords: reproducibility; retinal vasculature; angiography; foveal avascular; operator

Journal Title: Ophthalmic Research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.